Item # Model 335WP, Portable Process Analyzer for Hydrogen, Weatherproof (WP) Enclosure

Specifications

Method of Detection

Temperature compensated thermal conductivity (T/C) cell

Ranges Available

0-100% H2 in a binary gas mixture

Resolution

0.1% of H2

Accuracy & Repeatability

±2% of full scale

Drift

±1% of full scale per week

Response Time (T-90)

10-15 seconds to 90% step change - not including sample transport time

Ambient Temperature Range

12 to 50 ºC55 to 120 ºF

Linearity

±2% of F.S.

Size & Weight

10" L x 7 1/2" H x 6 1/2" D @ 8 lbs (25.5 x 19 x 16.5 cm @ 3.6 kg)

Power

AC/DC Operation. 115 VAC, 60 Hz for recharging (220 VAC, 50 Hz available)

Output Options

0-1 VDC4-20 mA

Alarms

H2 alarm with LED (optional)

Hazardous Area Rating Options

General Purpose, Non-Hazardous